Self-Closing Valve
Nominal Diameter:1/2″~36″(DN15-50)
Nominal Pressure:Class150(PN10)
Maximum Operating Temperature:Ambient Temperature
Shell Material:CAC403, CAC406, CAC408, C5191, CAC702, CAC703, CAC704, C6301, C6641, C4430, C90500, C90300, C90700, C51000, C95200, C95400, C95500, C63000, C66400, C65500,C70600, C71500, C83600, ASTM B505, ASTM B139, ASTM B150, ASTM B138, ASTM B98, ASTM B171,etc
Design Standards:ABS, BV, CCS, API 6D, API 608, ASME B16.34, GB/T 12237, GB/T 587, JIS B2071, JIS B2072, DIN 3202, etc
Connection:Flange or Welding
Drive Mode:Manual, Electric, Pneumatic, Hydraulic
Application Field:Marine engineering, Shipbuilding, Seawater Desalination, Offshore Platforms, Coastal Power Plants, Harbor Facilities, etc
Self-Closing Valve
Product Definition & Safety Mission:
Cryogenic Double Block & Bleed Ball Valves are core isolation equipment for ensuring the safety of cryogenic transport systems such as LNG and liquid nitrogen. As a key type of cryogenic valve, they achieve reliable bidirectional cutoff of the medium through two independent sealed valve seats and safely release valve cavity pressure via a dedicated vent, completely eliminating the risk of rupture caused by internal leakage and pressure buildup in the cavity. These cryogenic DBB valves maintain absolute sealing integrity even under extreme conditions of -196°C, providing ultimate safety assurance for the transport of cryogenic media.
JH Self-Closing Technology Core:
- Bidirectional zero-leakage seal: Leakage rate ≤ Class VI (API 598) | Eliminates media cross-contamination
- Cryogenic material system: -196℃ cryogenic treatment for 8 hours | Overcoming low-temperature brittleness of materials
- Cavity pressure safety relief: relief port diameter ≥ DN15 (API 6D) | Eliminates overpressure risk
- Fire-safe metal seals: API 607 certified | Maintain seal integrity in fire conditions
- Product Technical Analysis
- Spring return
- Gravity Assist
The core technology of the self-closing valve lies in its reliable reset energy storage and precise closing process control. Upon opening, it stores mechanical energy (spring compression or potential energy increase), which drives the valve disc to reset upon release. The spring undergoes stress relaxation and fatigue testing to ensure stable elasticity throughout its lifespan; the gravity-driven mechanism requires low friction and wear resistance. The closing process often integrates hydraulic damping to prevent violent impacts and achieve smooth, tight closure. The sealing pair uses a combination of a bronze valve disc and a rubber valve seat, utilizing self-closing force to form a seal. Each valve undergoes ≥10,000 cycle life and sealing tests to ensure long-term reliability.
This subcategory of marine bronze self-closing valves relies on a built-in helical spring to provide the reset force, can be installed in any direction, has no requirements on the installation direction, and is flexible in application.
Core Processes:
▌ Spring-forced reset → Pre-tensioned stainless steel spring provides constant closing torque, independent of gravity | Can be reliably installed and automatically shut off on horizontal, vertical, or inclined pipelines.
▌ Temporary Opening and Locking → Some models can be equipped with a temporary lock to keep the water in the open state. It can be manually unlocked to close the water. It balances temporary continuous water supply with intrinsic safety and is easy to operate.
▌ Corrosion-resistant spring cavity → The spring is isolated from the medium and placed in an independent sealed chamber to prevent corrosion failure | Ensures that the reset function remains reliable after long-term service.
▌ General Deck Certification → Holds CCS and BV type approvals for deck flush valves and sanitary water shut-off valves.
This Self-Closing Valve relies primarily on the valve disc’s own weight to close, supplemented by a lightly loaded spring, and is specifically optimized for vertically downward flow pipelines.
Core Processes:
▌Gravity-based closure → Valve disc design optimizes weight, utilizing gravity to achieve the main closing action | Simple structure, extremely high reliability, and few potential failure points.
▌Low operating force design → Low opening force, easy operation, ergonomic | Suitable for flushing or sampling points that require frequent, short-term opening.
▌ Vertical Flow Direction Marking → The valve body has a clear flow direction arrow to ensure correct installation for optimal gravity shut-off effect | Avoid functional failure due to incorrect installation.
Core Design & Advantages
- Forced automatic shutdown: Using a preloaded spring or gravity reset → automatically shuts off within 1-3 seconds after releasing the handle | Eliminates safety accidents and waste caused by human forgetfulness.
- Long-lasting corrosion resistance of bronze: The flow-through components are made of UNS C95800 aluminum bronze | Overcoming the rust and blockage caused by deck and damp compartments, with a service life far exceeding that of brass valves.
- Fully Certified and Compliant: Complies with classification society regulations for self-closing valves → Holds certificates such as ABS, CCS, and BV | Meets international standards, providing compliance assurance.
- Zero-leakage seal: The valve disc and the resilient valve seat fit precisely together → achieving a Class IV seal (ISO 5208) under self-closing force | eliminating dripping when closed.
- Flexible and reliable installation: spring type can be installed in any direction, gravity type has a minimalist structure | adaptable to various spatial orientations of ship piping systems.
- Easy and user-friendly operation: Optimized opening force and handle design | Low operating torque, suitable for frequent temporary use.
- Intrinsically safe design: defaults to “normally closed”, follows the fail-safe principle | provides redundant safety, and tends to close even in the event of unexpected failure.
Other Products
FAQ-Marine Self-Closing Valve
A Marine Self-Closing Valve is an automatic resetting safety valve specifically designed for marine piping systems handling flammable liquids such as fuel oil, lubricating oil, and hydraulic oil. Its primary purpose is to automatically close in the event of pipe rupture, fire, or emergency situations, preventing flammable liquid leakage that could cause fire or environmental pollution. It is typically installed at critical locations such as fuel oil tanks, lubricating oil tanks, service tanks, and fuel oil transfer lines, making it an essential component in marine fire safety systems.
Bronze offers the following core advantages for marine self-closing valves:
Superior Seawater Corrosion Resistance: Excellent resistance to seawater, salt spray, and marine atmospheres.
Non-Sparking: Bronze does not create sparks upon impact, suitable for environments with potential flammable gases.
Good Mechanical Properties: Maintains strength and toughness even at low temperatures.
Wear Resistance: Bronze disc and seat combinations offer good wear resistance, ensuring long-term reliable sealing.
Anti-Fouling Properties: Bronze surfaces resist marine growth, ensuring smooth valve operation.
Our Marine Self-Closing Valves are designed and manufactured in strict compliance with classification society rules and international safety standards, holding major certifications including API, ISO, CE, ABS, BV, and CCS. Additionally, the products comply with SOLAS (International Convention for the Safety of Life at Sea) Chapter II-2 requirements for fuel line safety, IMO (International Maritime Organization) regulations, and classification society standards for fire valves, ensuring compliance and reliability in global marine fuel oil systems.
The essential difference lies in the automatic resetting safety function:
| Aspect | Marine Self-Closing Valve | Standard Marine Globe Valve |
|---|---|---|
| Operation | Manual opening, automatic closing (self-resetting after release) | Manual opening, manual closing |
| Safety Function | Automatically shuts off fuel line during emergencies | No automatic shut-off function |
| Structural Design | Equipped with spring return mechanism | No automatic return mechanism |
| Application | Flammable liquid lines such as fuel oil, lubricating oil | General non-flammable media like seawater, fresh water |
| Regulatory Requirement | SOLAS mandatory requirement at fuel tank outlets | No special safety regulation requirement |
Typical installation locations include:
Fuel Oil Tank Outlets: Fuel oil service tanks, settling tanks, fuel oil tank outlets
Lubricating Oil Tank Outlets: Lubricating oil circulating tanks, storage tank outlets
Fuel Oil Transfer Lines: Fuel oil transfer pump discharges, fuel oil purification systems
Hydraulic Oil Systems: Hydraulic oil tank outlets
Flammable Liquid Storage Tanks: Various flammable media tank outlets
According to SOLAS Convention requirements, all fuel oil tank and lubricating oil tank outlets must be equipped with valves that can automatically shut off during emergencies.
Installation and maintenance points:
Installation Direction: Strictly follow the flow direction arrow marked on the valve body to ensure correct media flow.
Installation Location: Should be installed in easily accessible and unobstructed locations with pull cables or remote controls extending to safe areas.
Pull Cable/Remote Control: The remote operating cable for self-closing valves should extend to deck or safe locations and remain unobstructed.
Regular Function Testing: Recommended to perform open/close function testing at least monthly, pulling the cable to release and confirming the valve automatically resets to closed position.
Spring Inspection: Regularly inspect springs for fatigue or failure to ensure reliable automatic closing function.
Sealing Verification: Periodically verify sealing integrity in the closed position to prevent fuel oil leakage.
Common failures and countermeasures:
Automatic Closing Failure: May be caused by spring fatigue, sticking, or pull cable obstruction. Prevention includes regular function testing (monthly). Solution involves replacing springs, cleaning stems, or repairing pull cable mechanisms.
Seal Leakage: May be due to worn sealing surfaces, foreign object obstruction, or corrosion. Prevention includes regular inspection. Solution involves lapping sealing surfaces or replacing disc/seat.
Operation Sticking: May be caused by marine growth, corrosion product buildup, or poor lubrication. Prevention includes regular operation testing. Solution involves cleaning stems and applying marine-grade grease.
Pull Cable Failure: May be caused by cable rust, breakage, or sheave sticking. Prevention includes regular cable inspection. Solution involves replacing cables or repairing guide mechanisms.
For accurate selection, please provide:
Size & Pressure Rating: e.g., DN25, PN16 or 1″, Class 150
Connection Type: Flanged (standard & face type), threaded
Operation Method: Manual pull cable, push-pull cable, pneumatic, electric
Remote Control Requirements: Cable length, guide method, operating location
Classification Society Requirements: ABS, BV, CCS, LR, NK approval
Media Information: Media name (fuel oil, lubricating oil, hydraulic oil), temperature, pressure
Special Requirements: Fire-resistant coating, explosion-proof requirements, certification needs, special markings