x
Send Your Inquiry Today
Quick Quote

Emergency Shut-Off (Quick-Closing) Valve

Nominal Diameter:1/2”~8”(DN15-DN200)

Nominal Pressure:Class150

Maximum Operating Temperature:Ambient Temperature

Shell Material:CAC403, CAC406, CAC408, C5191, CAC702, CAC703, CAC704, C6301, C6641, C4430, C90500, C90300, C90700, C51000, C95200, C95400, C95500, C63000, C66400, C65500,C70600, C71500, C83600, ASTM B505, ASTM B139, ASTM B150, ASTM B138, ASTM B98, ASTM B171,etc

Design Standards:ABS, BV, CCS, API 6D, API 608, ASME B16.34, GB/T 12237, GB/T 587, JIS B2071, JIS B2072, DIN 3202, etc

Connection:Flange or Welding

Drive Mode:Manual, Electric, Pneumatic, Hydraulic

Application Field:Marine engineering, Shipbuilding, Seawater Desalination, Offshore Platforms, Coastal Power Plants, Harbor Facilities, etc

Emergency Shut-Off (Quick-Closing) Valve

Product Definition & Safety Mission:
The Emergency Shut-Off (Quick-Closing) Valve is a core safety terminal for ships and offshore platforms, enabling instantaneous remote cutoff of hazardous media during fires or leaks. The JH valve uses pre-tensioned energy storage with signal linkage, fully closing within ≤3 seconds on fire or ESD signal to isolate the hazard. It strictly complies with SOLAS and classification society standards as the final mechanical safety barrier.

JH Marine Bronze Lined Butterfly Valve Technology Core:

  • Seawater corrosion resistant: Valve body in UNS C95800 aluminum bronze, corrosion ≤ 0.025 mm/year (ASTM G48), >25 years life.
  • Zero-leakage sealing: Integral molded EPDM/NBR lining, leakage ≤ Class VI (ISO 5208), bidirectional bubble-tight shut-off.
  • Lightweight compact design: Wafer type per ISO 5752, weight 55% of cast steel valves, saving space and payload.
  • Global classification approval: Full type approval from ABS, BV, CCS, ensuring global compliance
Emergency Shut-Off (Quick-Closing) Valve 2

The core technology of the Emergency Shut-Off (Quick-Closing) Valve lies in the deep integration of its highly reliable triggering mechanism and extremely short stroke time control. The valve is typically in the fully open position and held by an energy storage mechanism (such as a spring) or pressurized fluid (hydraulic/pneumatic). Upon triggering, the release mechanism (such as a solenoid valve or fusible alloy) actuates, instantly releasing the stored energy and driving the valve disc (gate, ball, or swing valve disc) to overcome the fluid dynamics and friction, completing the closure within seconds. Its key design feature is the damping control of the closing process to avoid water hammer. Position feedback and a self-diagnostic system continuously monitor the valve’s readiness status, energy pressure, and signal circuits, ensuring it is always in a “ready” state. The emergency shut-off (quick-closing) valve is not merely a valve, but an integrated active safety system combining mechanical, fluid, and electrical controls, its reliability verified through ≥10,000 cycle life tests and rigorous type testing.

It relies on a pre-compression spring to provide the closing power, eliminating the need for continuous external energy or power source, and is inherently safe.

Core Processes:
▌ Spring-driven mechanical system → High-reliability helical spring with release mechanism consisting of a fusible alloy plug (melts at 70℃) or solenoid valve control | Automatic or remote triggering in case of fire to ensure reliable operation.
▌ Single-acting actuator → “Fail-safe” mode, automatically shuts down in case of power failure/gas failure | Provides intrinsically safe design.
▌ Position Holding and Indication → Normally open position is held by hydraulic damping or mechanical lock; with remote switch and local indication | Real-time monitoring of valve status.
▌ Marine Certification → Holds type approval certificates for quick-closing valves issued by ABS and BV.

Driven by a central power system, it is suitable for large cargo oil pipelines, large diameter pipelines, and high back pressure conditions.

Core Processes:
▌ Central power unit drive → Powered by a dedicated hydraulic station (pressure ≥160 bar) or instrument air central power supply | Powerful and responsive when shutting down.
▌Dual-acting/single-acting configuration → Can be designed to require power to open and maintain, or power to open and spring to close | to meet different system safety strategies.
▌ Redundant Control Loop → The control solenoid valve adopts a redundant design, receiving multiple signals | Multiple triggering protection.
▌ High integrity seal → The valve seat meets API 607 ​​fire resistance test and Class VI bubble seal requirements.

JH-Pneumatic-Actuator-1

Core Design & Advantages

  • Rapid shutdown in seconds: Employing a preloaded energy storage mechanism and low-friction design → Trigger to full shutdown time ≤ 3 seconds (IMO Guidelines) | Prevents escalation of hazards and gains valuable time for emergency response.
  • Multiple drive redundancy: Integrated spring, hydraulic, pneumatic and manual redundant drive methods | Ensure that the valve can still close reliably in the event of any single system failure.
  • Hazardous Area Certification: Meets ATEX Zone 1 explosion protection requirements, with actuator protection rating of IP66/IP67 | Overcoming the challenges of application in flammable and explosive environments.
JH Production Equipment (1)
JH machine lathe

  • Intrinsic safety logic: default “fail-safe” design | provides the highest level of safety redundancy.
  • Intelligent monitoring and feedback: Standard configuration includes valve position transmitter and remote alarm contact | Enables real-time central monitoring of valve status, eliminating safety blind spots.
  • Long lifespan and maintenance-free: Key components are equipped with wear-resistant bushings and coatings | It can maintain a maintenance-free cycle of up to 5 years in standby mode.

FAQ-Emergency Shut-Off (Quick-Closing) Valve

What is an Emergency Shut-Off Valve (Quick-Closing Valve) and what is its primary purpose?

An Emergency Shut-Off Valve, also known as a Quick-Closing Valve, is a safety protection valve designed to rapidly isolate media flow during emergency situations. It is typically installed at critical locations such as fuel oil systems, LPG storage tanks, chemical pipelines, and marine engine rooms. When emergencies such as fire, pipeline rupture, leakage, or overpressure occur, it can quickly shut off the pipeline to prevent accident escalation and ensure personnel and equipment safety.

What is the essential difference between an Emergency Shut-Off Valve and a standard globe valve?

The essential difference lies in safety function design:

AspectEmergency Shut-Off ValveStandard Globe Valve
Closing SpeedRapid closure within secondsSlow manual operation
Operation MethodRemote control, automatic trip, manual quick-closeConventional handwheel operation
Safety RedundancyEquipped with fail-safe mechanismNo special safety design
Actuation ModeAutomatically triggered by fire, leakage, overpressure signalsManual operation
Reliability RequirementStandby for long periods, must operate reliably at any timeReliable under normal operating frequency
What important international certifications do your Emergency Shut-Off Valves comply with?

Our Emergency Shut-Off Valves are designed and manufactured in strict compliance with international safety codes and classification society standards, holding major certifications including API, ISO, CE, ABS, BV, and CCS. Additionally, the products comply with API 607 / ISO 10497 fire test standards, SIL (Safety Integrity Level) certification, and various industry safety regulations, ensuring reliable shut-off performance during emergencies.

What are the common operation and actuation methods for Emergency Shut-Off Valves?

Multiple operation and actuation methods are available:

  • Manual Quick-Close: Pull cable, push-pull cable, or handle for on-site rapid manual closure

  • Pneumatic Operation: Compressed air-driven actuator for remote or automatic control

  • Hydraulic Operation: Suitable for high-pressure or high-torque applications, smooth and reliable

  • Solenoid Operation: Electric signal-triggered, fast response

  • Fusible Link Trigger: Fusible alloy melts at fire temperature, automatically closing the valve

  • Overpressure/Leakage Automatic Trigger: Automatically shuts off upon detecting pressure anomaly or leakage

What does "fail-safe" mode mean for Emergency Shut-Off Valves and what types are available?

“Fail-safe” means the valve automatically returns to a preset safe state upon power failure or emergency signal activation. Common types include:

  • Fail-Closed (FC): Valve automatically closes upon power loss or emergency signal, commonly used to prevent media leakage or fire spread.

  • Fail-Open (FO): Valve automatically opens upon power loss, suitable for applications requiring continuous cooling or pressure relief.

  • Fail-Last (FL): Valve maintains its current position upon power loss, suitable for applications requiring process stability.
    For Emergency Shut-Off Valves, Fail-Closed is the most common safety mode.

What are the key considerations for installing and maintaining an Emergency Shut-Off Valve?

Installation and maintenance points:

  • Installation Location: Should be installed in easily accessible locations away from hazards, with manual quick-close devices extending to safe areas.

  • Flow Direction Confirmation: Strictly follow the flow direction arrow marked on the valve body.

  • Regular Testing: Recommended to perform functional testing at least monthly to ensure reliable operation during emergencies.

  • Fusible Alloy Inspection: For fusible link type valves, regularly inspect the fusible alloy for integrity.

  • Actuator Maintenance: Check pneumatic/hydraulic actuator air/oil supply; verify solenoid coil condition.

  • Sealing Verification: Periodically verify sealing integrity in the closed position.

  • Operation Records: Establish testing and maintenance record logs for traceability.

紧急切断阀的响应时间通常是多久?如何确保快速关闭?

Response time depends on valve type and actuation method:

  • Manual Quick-Close: Typically closes within 2-5 seconds

  • Pneumatic/Hydraulic: Typically closes within 1-3 seconds

  • Solenoid Operation: Typically closes within 0.5-2 seconds

  • Fusible Link: Automatically closes when temperature reaches set point

Measures to ensure rapid closure include:

  • Selecting high-flow actuators with sufficient driving force

  • Maintaining stable air/oil supply pressure

  • Regular testing to ensure no sticking of moving parts

  • Using spring-return fail-safe designs

What key parameters should be provided when ordering an Emergency Shut-Off Valve?

For accurate selection, please provide:

  • Size & Pressure Rating: e.g., DN50, PN40 or 2″, Class 300

  • Valve Type: Ball valve, butterfly valve, globe valve, etc.

  • Connection Type: Flanged, butt weld, threaded

  • Operation & Actuation Method: Manual quick-close, pneumatic, hydraulic, solenoid, fusible link, etc.

  • Fail-Safe Mode: Fail-Closed, Fail-Open, Fail-Last

  • Actuator Specifications: Air/electrical supply requirements, signal type, explosion-proof rating

  • Media Information: Media name, temperature, pressure, corrosiveness

  • Classification Society Requirements: ABS, BV, CCS, LR, NK approval

  • Certification Requirements: SIL rating, fire-safe certification, explosion-proof certification, etc.

Quick Quote