Emergency Shut-Off (Quick-Closing) Valve
Nominal Diameter:1/2”~8”(DN15-DN200)
Nominal Pressure:Class150
Maximum Operating Temperature:Ambient Temperature
Shell Material:CAC403, CAC406, CAC408, C5191, CAC702, CAC703, CAC704, C6301, C6641, C4430, C90500, C90300, C90700, C51000, C95200, C95400, C95500, C63000, C66400, C65500,C70600, C71500, C83600, ASTM B505, ASTM B139, ASTM B150, ASTM B138, ASTM B98, ASTM B171,etc
Design Standards:ABS, BV, CCS, API 6D, API 608, ASME B16.34, GB/T 12237, GB/T 587, JIS B2071, JIS B2072, DIN 3202, etc
Connection:Flange or Welding
Drive Mode:Manual, Electric, Pneumatic, Hydraulic
Application Field:Marine engineering, Shipbuilding, Seawater Desalination, Offshore Platforms, Coastal Power Plants, Harbor Facilities, etc
Emergency Shut-Off (Quick-Closing) Valve
Product Definition & Safety Mission:
The Emergency Shut-Off (Quick-Closing) Valve is a core safety terminal for ships and offshore platforms, enabling instantaneous remote cutoff of hazardous media during fires or leaks. The JH valve uses pre-tensioned energy storage with signal linkage, fully closing within ≤3 seconds on fire or ESD signal to isolate the hazard. It strictly complies with SOLAS and classification society standards as the final mechanical safety barrier.
JH Marine Bronze Lined Butterfly Valve Technology Core:
- Seawater corrosion resistant: Valve body in UNS C95800 aluminum bronze, corrosion ≤ 0.025 mm/year (ASTM G48), >25 years life.
- Zero-leakage sealing: Integral molded EPDM/NBR lining, leakage ≤ Class VI (ISO 5208), bidirectional bubble-tight shut-off.
- Lightweight compact design: Wafer type per ISO 5752, weight 55% of cast steel valves, saving space and payload.
- Global classification approval: Full type approval from ABS, BV, CCS, ensuring global compliance
- Product Technical Analysis
- Spring Energy Storage
- Hydraulic/Pneumatic
The core technology of the Emergency Shut-Off (Quick-Closing) Valve lies in the deep integration of its highly reliable triggering mechanism and extremely short stroke time control. The valve is typically in the fully open position and held by an energy storage mechanism (such as a spring) or pressurized fluid (hydraulic/pneumatic). Upon triggering, the release mechanism (such as a solenoid valve or fusible alloy) actuates, instantly releasing the stored energy and driving the valve disc (gate, ball, or swing valve disc) to overcome the fluid dynamics and friction, completing the closure within seconds. Its key design feature is the damping control of the closing process to avoid water hammer. Position feedback and a self-diagnostic system continuously monitor the valve’s readiness status, energy pressure, and signal circuits, ensuring it is always in a “ready” state. The emergency shut-off (quick-closing) valve is not merely a valve, but an integrated active safety system combining mechanical, fluid, and electrical controls, its reliability verified through ≥10,000 cycle life tests and rigorous type testing.
It relies on a pre-compression spring to provide the closing power, eliminating the need for continuous external energy or power source, and is inherently safe.
Core Processes:
▌ Spring-driven mechanical system → High-reliability helical spring with release mechanism consisting of a fusible alloy plug (melts at 70℃) or solenoid valve control | Automatic or remote triggering in case of fire to ensure reliable operation.
▌ Single-acting actuator → “Fail-safe” mode, automatically shuts down in case of power failure/gas failure | Provides intrinsically safe design.
▌ Position Holding and Indication → Normally open position is held by hydraulic damping or mechanical lock; with remote switch and local indication | Real-time monitoring of valve status.
▌ Marine Certification → Holds type approval certificates for quick-closing valves issued by ABS and BV.
Driven by a central power system, it is suitable for large cargo oil pipelines, large diameter pipelines, and high back pressure conditions.
Core Processes:
▌ Central power unit drive → Powered by a dedicated hydraulic station (pressure ≥160 bar) or instrument air central power supply | Powerful and responsive when shutting down.
▌Dual-acting/single-acting configuration → Can be designed to require power to open and maintain, or power to open and spring to close | to meet different system safety strategies.
▌ Redundant Control Loop → The control solenoid valve adopts a redundant design, receiving multiple signals | Multiple triggering protection.
▌ High integrity seal → The valve seat meets API 607 fire resistance test and Class VI bubble seal requirements.
Core Design & Advantages
- Rapid shutdown in seconds: Employing a preloaded energy storage mechanism and low-friction design → Trigger to full shutdown time ≤ 3 seconds (IMO Guidelines) | Prevents escalation of hazards and gains valuable time for emergency response.
- Multiple drive redundancy: Integrated spring, hydraulic, pneumatic and manual redundant drive methods | Ensure that the valve can still close reliably in the event of any single system failure.
- Hazardous Area Certification: Meets ATEX Zone 1 explosion protection requirements, with actuator protection rating of IP66/IP67 | Overcoming the challenges of application in flammable and explosive environments.
- Intrinsic safety logic: default “fail-safe” design | provides the highest level of safety redundancy.
- Intelligent monitoring and feedback: Standard configuration includes valve position transmitter and remote alarm contact | Enables real-time central monitoring of valve status, eliminating safety blind spots.
- Long lifespan and maintenance-free: Key components are equipped with wear-resistant bushings and coatings | It can maintain a maintenance-free cycle of up to 5 years in standby mode.
Other Products
FAQ-Emergency Shut-Off (Quick-Closing) Valve
An Emergency Shut-Off Valve, also known as a Quick-Closing Valve, is a safety protection valve designed to rapidly isolate media flow during emergency situations. It is typically installed at critical locations such as fuel oil systems, LPG storage tanks, chemical pipelines, and marine engine rooms. When emergencies such as fire, pipeline rupture, leakage, or overpressure occur, it can quickly shut off the pipeline to prevent accident escalation and ensure personnel and equipment safety.
The essential difference lies in safety function design:
| Aspect | Emergency Shut-Off Valve | Standard Globe Valve |
|---|---|---|
| Closing Speed | Rapid closure within seconds | Slow manual operation |
| Operation Method | Remote control, automatic trip, manual quick-close | Conventional handwheel operation |
| Safety Redundancy | Equipped with fail-safe mechanism | No special safety design |
| Actuation Mode | Automatically triggered by fire, leakage, overpressure signals | Manual operation |
| Reliability Requirement | Standby for long periods, must operate reliably at any time | Reliable under normal operating frequency |
Our Emergency Shut-Off Valves are designed and manufactured in strict compliance with international safety codes and classification society standards, holding major certifications including API, ISO, CE, ABS, BV, and CCS. Additionally, the products comply with API 607 / ISO 10497 fire test standards, SIL (Safety Integrity Level) certification, and various industry safety regulations, ensuring reliable shut-off performance during emergencies.
Multiple operation and actuation methods are available:
Manual Quick-Close: Pull cable, push-pull cable, or handle for on-site rapid manual closure
Pneumatic Operation: Compressed air-driven actuator for remote or automatic control
Hydraulic Operation: Suitable for high-pressure or high-torque applications, smooth and reliable
Solenoid Operation: Electric signal-triggered, fast response
Fusible Link Trigger: Fusible alloy melts at fire temperature, automatically closing the valve
Overpressure/Leakage Automatic Trigger: Automatically shuts off upon detecting pressure anomaly or leakage
“Fail-safe” means the valve automatically returns to a preset safe state upon power failure or emergency signal activation. Common types include:
Fail-Closed (FC): Valve automatically closes upon power loss or emergency signal, commonly used to prevent media leakage or fire spread.
Fail-Open (FO): Valve automatically opens upon power loss, suitable for applications requiring continuous cooling or pressure relief.
Fail-Last (FL): Valve maintains its current position upon power loss, suitable for applications requiring process stability.
For Emergency Shut-Off Valves, Fail-Closed is the most common safety mode.
Installation and maintenance points:
Installation Location: Should be installed in easily accessible locations away from hazards, with manual quick-close devices extending to safe areas.
Flow Direction Confirmation: Strictly follow the flow direction arrow marked on the valve body.
Regular Testing: Recommended to perform functional testing at least monthly to ensure reliable operation during emergencies.
Fusible Alloy Inspection: For fusible link type valves, regularly inspect the fusible alloy for integrity.
Actuator Maintenance: Check pneumatic/hydraulic actuator air/oil supply; verify solenoid coil condition.
Sealing Verification: Periodically verify sealing integrity in the closed position.
Operation Records: Establish testing and maintenance record logs for traceability.
Response time depends on valve type and actuation method:
Manual Quick-Close: Typically closes within 2-5 seconds
Pneumatic/Hydraulic: Typically closes within 1-3 seconds
Solenoid Operation: Typically closes within 0.5-2 seconds
Fusible Link: Automatically closes when temperature reaches set point
Measures to ensure rapid closure include:
Selecting high-flow actuators with sufficient driving force
Maintaining stable air/oil supply pressure
Regular testing to ensure no sticking of moving parts
Using spring-return fail-safe designs